Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Mol Mutagen ; 53(3): 185-97, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22246666

RESUMO

An international round-robin study on the Ames fluctuation test [ISO 11350, 2012], a microplate version of the classic plate-incorporation method for the detection of mutagenicity in water, wastewater and chemicals was performed by 18 laboratories from seven countries. Such a round-robin study is a precondition for both the finalization of the ISO standardization process and a possible regulatory implementation in water legislation. The laboratories tested four water samples (spiked/nonspiked) and two chemical mixtures with and without supplementation of a S9-mix. Validity criteria (acceptable spontaneous and positive control-induced mutation counts) were fulfilled by 92-100%, depending on the test conditions. A two-step method for statistical evaluation of the test results is proposed and assessed in terms of specificity and sensitivity. The data were first subjected to powerful analysis of variance (ANOVA) after an arcsine-square-root transformation to detect significant differences between the test samples and the negative control (NC). A threshold (TH) value based on a pooled NC was then calculated to exclude false positive test results. Statistically, positive effects observed by the William's test were considered negative, if the mean of all replicates of a sample did not exceed the calculated TH. By making use of this approach, the overall test sensitivity was 100%, and the test specificity ranged from 80 to 100%.


Assuntos
Testes de Mutagenicidade/métodos , Testes de Mutagenicidade/normas , Resíduos , Poluentes Químicos da Água/toxicidade , Animais , Masculino , Testes de Mutagenicidade/estatística & dados numéricos , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Salmonella/efeitos dos fármacos , Salmonella/genética
2.
Water Sci Technol ; 63(1): 72-9, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21245556

RESUMO

In the frame of the European FP6 project Neptune, a combination of biological activated carbon with ultrafiltration (BioMAC) was investigated for micropollutant, pathogen and ecotoxicity removal. One pilot scale set-up and two lab-scale set-ups, of which in one set-up the granular activated carbon (GAC) was replaced by sand, were followed up during a period of 11 months. It was found that a combination of GAC and ultrafiltration led to an almost complete removal of antibiotics and a high removal (>80%) of most of the investigated acidic pharmaceuticals and iodinated contrast media. The duration of the tests did however not allow to conclude that the biological activation was able to extend the lifetime of the GAC. Furthermore, a significant decrease in estrogenic and anti-androgenic activity could be illustrated. The set-up in which GAC was replaced by sand showed a considerably lower removal efficiency for micropollutants, especially for antibiotics but no influence on steroid activity.


Assuntos
Carbono/química , Membranas Artificiais , Ultrafiltração/métodos , Poluentes da Água/química , Projetos Piloto , Poluentes da Água/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...